Chalco supplies 1350 EC grade aluminum wire for electrical conductor applications, with product selection based on wire diameter, temper, conductivity, mechanical requirements and order specifications. Aluminum 1350 wire is used in conductor manufacturing, including applications requiring electrical-grade round wire.
The product range also covers 1350 aluminum drawing stock and wire rod for customers with upstream processing requirements. Chalco supports specification review, conductor-material selection, processing coordination and agreed material inspection documentation. Finished-wire availability and drawing-stock supply are reviewed separately for each order.
1350 Aluminum Wire Supply and Manufacturing
Chalco supports electrical-grade aluminum supply from 1350 drawing stock through selected finished-wire configurations. Production and sourcing arrangements are reviewed against the required material condition, wire dimensions, electrical properties, inspection plan and order quantity.
For finished electrical wire, procurement review focuses on conductor-wire diameter, temper, resistivity, tensile requirements, continuous length, reel or coil packaging and applicable test records. Drawing stock is a separate supply category; its casting-and-rolling route, coil weight and redraw dimensions are not presented as finished-wire specifications.
1350 Aluminum Wire and Wire Rod Specifications
Specify the required product form first: finished electrical round wire or aluminum drawing stock. Diameter, temper and acceptance criteria are evaluated for the chosen product form rather than using one specification for both.
| Purchase item | Finished electrical aluminum wire | 1350 drawing stock / wire rod |
| Product form | Electrical-grade round aluminum wire for conductor processing | Aluminum redraw rod / drawing stock for downstream wire drawing |
| Alloy / condition | 1350; specify required temper, including H19 where applicable | 1350; stock temper based on the applicable drawing-stock specification |
| Dimensions | Specify finished wire diameter and tolerance; available range reviewed for the order | Specify redraw diameter, coil form and required quantity; applicability reviewed separately |
| Technical requirements | Resistivity, tensile strength, elongation and applicable inspection conditions | Drawing suitability, chemistry, mechanical condition and resistivity of stock |
| Packaging | Required continuous length, reel or coil type and shipment protection | Coil dimensions, identification and protective packing as specified |
| Standards | ASTM B230/B230M for specified 1350-H19 round wire; apply only where ordered and verified | ASTM B233 for applicable 1350 electrical drawing stock |
Finished-wire orders: Specify the required 1350 aluminum wire diameter and tolerance, temper (including H19 where applicable), electrical resistance or conductivity, tensile requirements, continuous wire length, reel or coil format, quantity and destination. Chalco reviews the requested wire configuration against the applicable purchase specification; no universal finished-wire diameter range or stock availability is implied.
Wire rod orders: Drawing stock is quoted separately by redraw diameter, material condition, coil requirements and order quantity.
Share your required 1350 aluminum wire diameter, temper, conductivity and mechanical specifications for material selection, technical review and quotation.
Electrical Conductivity of 1350 Aluminum
Electrical conductivity and resistivity depend on material condition and the applicable product specification. The following values are published drawing-stock references from the existing 1350 wire rod content, not test values for 1350-H19 finished electrical wire.
| Temper | Resistivity (nOhmm) | Conductivity (% IACS) |
| H15 | 28.01 | 61.5 |
| H14 | 28.01 | 61.5 |
| H13 | 28.01 | 61.5 |
| H12 | 28.01 | 61.5 |
| H11 | 27.85 | 61.9 |
| O | 27.35 | 63 |
Share your required 1350 aluminum wire diameter, temper, quantity and packaging specifications for available product options and quotation.
1350 Wire Rod Mechanical Properties
The tensile strength and elongation values below describe the wire-rod material conditions listed in the original product references. Finished 1350 electrical wire, including H19 wire, is evaluated separately under its specified product requirements.
| Temper | Tensile strength (MPa) | Elongation 200mm (%) | |
| min. | max. | ||
| H15 | 125 | 140 | 5-15 |
| H14 | 115 | 130 | 5-15 |
| H13 | 105 | 120 | 7-20 |
| H12 | 95 | 110 | 10-30 |
| H11 | 80 | 95 | 15-35 |
| O | 60 | 80 | 30-50 |
1350 Electrical Aluminum Wire Advantages
Electrical-grade material: 1350 aluminum provides a conductor-material option where resistivity and material condition are key selection requirements.
Defined wire properties: Finished-wire tensile, elongation and electrical properties can be specified by the applicable product standard and order requirements.
Wire processing options: Diameter, wire condition, drawing and supply format are reviewed against the intended conductor manufacturing process.
Conductor manufacturing: 1350 wire is relevant to electrical conductor production, while completed stranded conductor constructions are defined by their own specifications.
Material and shipment traceability: Lot identification, inspection documentation and packaging requirements can be agreed for the order.
Chalco supports 1350 electrical aluminum wire selection based on conductivity, tensile strength and processing requirements. Submit your technical specifications for material matching and quotation.
1350 Aluminum Wire Applications
Electrical-grade 1350 aluminum wire is used as a constituent wire in specified conductor products. Finished-wire and stranded-conductor orders have different diameter, strength, construction, packing and inspection requirements.
All-Aluminum Conductors (AAC): 1350 aluminum wire is a relevant component material for concentric-lay-stranded aluminum conductors, subject to the specified wire temper and conductor construction. See the overhead AAC, AAAC and ACSR conductor options for finished-conductor configurations.
Aluminum Conductor Steel Reinforced (ACSR): 1350-H19 aluminum wires may be used with specified steel-reinforced conductor constructions; component-wire supply and complete ACSR conductor products must be distinguished.
Aluminum Conductor Alloy Reinforced (ACAR): 1350 high-conductivity aluminum wire may be used as the current-carrying outer material in specified ACAR conductor constructions, with an aluminum-alloy reinforcing core selected to meet mechanical requirements. For alloy-wire strength requirements, see 6201 aluminum wire for AAAC; it is a different alloy and component-wire specification.
Electrical conductor processing: Finished single-wire material can be specified for further stranding or cable manufacturing where its electrical and mechanical properties suit the conductor design.
Drawing-stock applications: Aluminum 1350 wire rod is an upstream input for wire drawing, not a finished conductor or insulated cable.
Conductor-wire supply: Submit the required 1350 round-wire diameter, temper, quantity and applicable standard for conductor-wire sourcing. Complete stranded conductors require a separate construction specification and quotation; 1350 wire rod is evaluated only when redraw stock is explicitly requested.
Project Solutions for Electrical Conductors
Chalco supports electrical conductor projects with specified 1350 round aluminum wire and related material, structural and connection-component options. For a different conductor form, compare 1350/1370 aluminum busbars; these are rigid products, not wire-rod substitutes. Supply coordination follows the project specification; complete system engineering and installation remain outside the material supply scope.
Overhead-line connection components: Conductor suspension, tension anchoring and line connection requirements can be reviewed together with compatible overhead-line accessories. Hardware selection remains subject to the conductor type, mechanical load, connection structure and project specification.
Electrical structural profiles: Where a project also requires equipment frames, support profiles, protective structures or customized extruded sections, applicable 6005/6005A aluminum extrusion solutions can be evaluated separately from the current-carrying 1350 wire. Likewise, 1350/1370 tubular bus conductors are a different current-carrying product form.
Project supply support: Material specifications, conductor-related components, structural interfaces and compatible aluminum, copper and bimetallic connectors can be reviewed against customer drawings and purchase requirements.
Share the conductor construction, wire specifications, mechanical interfaces, electrical requirements and project drawings for material selection, compatible product options and quotation.
Chalco supports electrical conductor projects with 1350 aluminum wire, related conductor materials and connection components. Share your project drawings, conductor requirements and order details for coordinated supply and quotation.
Related Electrical Aluminum Wire and Wire Rod Products
Compare related electrical aluminum wire and wire rod options by product form, alloy and conductivity, including 1050/1070/1080 EC-grade wire rods. Finished wire and redraw stock remain separate purchase forms with their own acceptance criteria.
1350 Wire and Drawing Stock Order Requirements
Supply specifications differ between finished electrical wire and redraw stock. Use the following purchase checklist to prepare a drawing-based or standards-based inquiry.
| Requirement | Information to provide |
| Product form | 1350 finished round electrical wire or 1350 redraw rod |
| Alloy and temper | 1350 and the specified material condition |
| Dimensions | Finished wire diameter and tolerance, or drawing-stock diameter as applicable |
| Electrical and mechanical criteria | Required resistivity/conductivity, tensile strength and elongation |
| Order and packaging | Quantity, reel/coil requirements, continuous length and delivery destination |
| Inspection and standards | Applicable product standard, test requirements and requested documentation |
Frequently Asked Questions
What is the difference between 1350 aluminum wire and wire rod?
1350 wire rod is drawing stock used to produce smaller wire. Finished electrical wire is ordered to its own diameter, temper, resistance and mechanical property requirements.
Is 1350-H19 aluminum wire covered by ASTM B230/B230M?
ASTM B230/B230M covers 1350-H19 round aluminum wire for electrical purposes. Specify this standard when the ordered finished-wire product and inspection scope are applicable.
Can 1350 aluminum wire be used for AAC and ACSR?
1350 wire is used in relevant electrical conductor constructions. AAC and ACSR have separate stranded-conductor specifications, and the requested supply form must be identified.
Which specifications are required for a 1350 electrical wire quotation?
Provide wire diameter, temper, quantity, applicable standard, required electrical and mechanical properties, reel or coil preferences and delivery destination.
Request 1350 Aluminum Wire Supply
Chalco supports 1350 electrical aluminum wire orders for conductor manufacturing, including specified wire diameters, tempers, electrical and mechanical acceptance criteria, and reel or coil requirements. Share the drawings or purchase specifications, quantity and destination for supply review and quotation. Aluminum drawing stock can be discussed separately when required.
Chalco can provide you the most comprehensive inventory of aluminum products and can also supply you customized products. Precise quotation will be provided within 24 hours.
Get a quote